- Turn off power before installing or servicing the chemical metering pump.
- Install only in a compatible low-pressure chemical feed system rated for the pump output and pressure.
- Confirm the pump voltage is 120V 60Hz before wiring or connecting power.
- Confirm the system requires a fixed-output double-head pump with 170 GPD output before installation.
- Use the correct 3/8" suction and discharge tubing for this pump configuration.
- Use the correct low-pressure injection fitting for 25 PSI applications.
- Do not substitute a 100 PSI injection check valve unless the application and pump configuration are specifically verified.
- Install the pump in a dry, secure, accessible location where it can be serviced.
- Mount the pump securely using the proper mounting bracket or mounting surface.
- Keep the pump above the chemical solution tank when practical and follow Stenner installation guidelines.
- Verify the suction line, discharge line, injection point, tubing connections, and chemical tank are correctly installed before startup.
- Prime the pump according to the Stenner instructions after installation.
- Check all tubing connections and injection points for leaks before leaving the system unattended.
- Calibrate the pump output in the field using analytical testing because actual output can vary with installation conditions.
- Do not install this pump if the application requires a different flow rate, pressure rating, voltage, tubing size, tube material, or adjustable-output configuration.
Product Highlights
- Stenner 170DMP5 Classic Series chemical metering pump
- Double-head fixed-output pump configuration
- 170 GPD fixed output for compatible low-pressure chemical feed applications
- 25 PSI maximum operating pressure
- 120V 60Hz single-phase motor
- Uses #5 Santoprene pump tubes
- Includes 20' of 3/8" white LDPE suction/discharge tubing
- Fixed-output design for timer, relay, or controller-based feed operation
- QuickPro pump heads support easier tube replacement
- Verify flow rate, pressure, voltage, tubing size, and chemical compatibility before ordering
Stenner 170DMP5 Fixed 3/8" White Tubing 170 GPD 25 PSI | 170FL5A3S
The following product(s) can expose you to chemicals which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov.
Stenner 170FL5A3S is a Classic Series 170DMP5 double-head fixed-output chemical metering pump for compatible pool, spa, and water treatment chemical feed applications. This pump is configured for low-pressure chemical feed systems up to 25 PSI and delivers a fixed output of 170 gallons per day.
This 170DMP5 pump uses #5 Santoprene pump tubes and 3/8" white LDPE suction/discharge tubing. The fixed-output design does not use a manual feed rate dial. Pump output is determined by the motor gear speed and pump tube size, making this model a good choice where a steady high-volume chemical feed rate is needed and output is controlled by run time, a timer, relay, or compatible chemical automation controller.
The Stenner Classic Series peristaltic design uses roller assemblies to compress the pump tubes and move chemical solution through the feed system. The double-head configuration provides higher output than comparable single-head models while maintaining the serviceable Stenner QuickPro pump head design.
Use this pump for compatible chlorine, acid, sanitizer, pH control, or other chemical feed applications where the chemical, concentration, pressure, tubing material, and system conditions are compatible. Always verify the required feed rate, system pressure, voltage, tubing size, chemical compatibility, injection fitting, and installation configuration before ordering or installing a chemical metering pump.
| SKU | 35-200-06244 |
|---|---|
| Manufacturer SKU | 170FL5A3S |
| Manufacturer | STENNER PUMP COMPANY |
| Brand | STENNER |
| Phase | 1 PH |
| Size | 3/8" Tubing |
| Horsepower | 1/30 HP |
| Pool Type | In Ground |
| Product Group | Chemical Metering Pump |
| Input Voltage | 120V |
| Cable Length (Ft) | 6' |
| Max Operating Pressure | 25 PSI |
| Flow Rate | 170 GPD |
| Style | Fixed Output |
| Tubing | Clear LDPE |
| Peristaltic Tube Material | Santoprene |
| In Stock | In Stock |
| Amp Draw | 1.7 |
| Compatible Model | Compatible Brand | Notes |
|---|---|---|
| Classic Series Double Head Fixed / 170F / 170DMP5 / 170FL5A3S | Stenner | Complete Stenner Classic Series 170DMP5 double-head fixed-output chemical metering pump with #5 Santoprene tubes, 3/8" tubing, 120V 60Hz motor, 170 GPD fixed output, and 25 PSI maximum pressure. Verify voltage, pressure rating, tube number, tubing size, output requirement, and chemical compatibility before ordering. |
| Low-Pressure Chemical Feed Systems / 25 PSI Max | Stenner | Suitable for compatible low-pressure chemical feed applications up to 25 PSI where a fixed-output double-head pump with 170 GPD output is required. For 25 PSI installations, use the proper low-pressure injection fitting rather than a 100 PSI injection check valve unless the application is specifically verified. |
| 3/8" Tubing Chemical Feed Installations | Stenner | Configured for compatible 3/8" suction and discharge tubing installations. Verify tubing material, connection style, injection fitting, suction strainer, and chemical compatibility before installation. |
| #5 Santoprene Pump Tube Applications | Stenner | Uses #5 Santoprene pump tubes. Tube number affects pump output, so verify the tube number before replacing pump tubes, pump heads, or pump head components. |
- Stenner 170DMP5 double-head fixed-output chemical metering pump
- Installed #5 Santoprene pump tubes
- Additional #5 Santoprene replacement pump tube
- 20' roll of 3/8" white LDPE suction/discharge tubing
- 3/8" connecting nuts
- 1/4" ferrules for compatible Stenner pump tube connections and 3/8" adapter assemblies
- 25 PSI low-pressure injection fitting
- 3/8" weighted suction line strainer
- Additional pump head latches
- Mounting bracket
- Quick Start Manual / installation documentation
Installation Notes
Usage / Safety Information
Usage Instructions
- Confirm the pump is installed with compatible chemical solution and tubing.
- Confirm the chemical tank has adequate solution before operation.
- Confirm the suction line is fully seated and properly connected.
- Confirm the discharge line is connected to the correct injection fitting.
- Confirm both pump tubes are the correct #5 Santoprene tubes.
- Turn the chemical feed system on according to site procedures.
- Allow the pump to prime before relying on chemical feed output.
- Verify that chemical solution is moving through the tubing.
- Check the suction line, discharge line, pump heads, and injection point for leaks.
- Use run time, a timer, relay, or compatible controller to manage the fixed chemical feed output.
- Test the pool or water system after adequate circulation time.
- Adjust run time, controller settings, or solution strength as needed to reach the desired chemical level.
- Inspect both pump tubes regularly for flattening, cracking, swelling, brittleness, or leakage.
- Replace pump tubes as part of routine maintenance or whenever feed output becomes inconsistent.
- Inspect tubing, fittings, ferrules, connecting nuts, injection fittings, and suction strainers during service.
- Keep the pump and chemical feed area clean, dry, and accessible.
Safety Information
- Use only with compatible chemicals, tubing, fittings, and system pressure.
- Always follow the Stenner pump manual and chemical manufacturer instructions.
- Disconnect electrical power before installing or servicing the pump.
- Use a qualified technician for electrical work when required.
- Relieve pressure before opening the pump heads or disconnecting tubing.
- Wear chemical-resistant gloves and eye protection when handling chemical feed equipment.
- Avoid contact with chlorine, acid, or other concentrated chemical solutions.
- Do not mix pool chemicals.
- Do not operate the pump with pump head covers removed.
- Do not operate the pump if tubing, fittings, pump head components, electrical components, or the injection point are leaking or damaged.
- Do not exceed the 25 PSI maximum pressure rating for this pump configuration.
- Do not run the pump with incompatible tubing or chemicals.
- Keep children away from chemical feed equipment and chemical storage areas.
- Store chemicals according to the chemical manufacturer's instructions.
- If chemical exposure occurs, follow the chemical label or SDS instructions.
Important Notes
- 170FL5A3S is a complete Stenner 170DMP5 double-head fixed-output chemical metering pump.
- This pump is rated for 170 GPD fixed output.
- This pump is rated for 25 PSI maximum pressure.
- This pump uses #5 Santoprene pump tubes.
- This pump is configured with 3/8" white LDPE suction/discharge tubing.
- This is a fixed-output pump, not an adjustable-output pump.
- Fixed-output pump feed rate is controlled by pump run time, external control, or system design, not by a manual feed rate dial.
- For an adjustable-output version, use the compatible adjustable 170DM5 model when manual output adjustment is needed.
- For 25 PSI low-pressure applications, Stenner uses an injection fitting rather than the 100 PSI injection check valve configuration.
- Actual pump output can vary based on installation conditions and should be field calibrated with water testing or analytical testing.
- Chemical compatibility depends on the chemical being pumped, concentration, temperature, pressure, tubing material, and operating conditions.
- This product is not a replacement pump tube, pump head, motor service kit, injection fitting, or tubing-only item.
- Double-head pumps may use different standard and innermost pump head parts, so verify pump head position when ordering replacement pump head components.
- Do not choose a chemical feed pump based only on horsepower or appearance.
- Verify required gallons per day, pressure rating, voltage, tubing size, fixed-output requirement, and chemical compatibility before ordering.
- The GTIN/UPC should be verified against supplier packaging before final product feed submission if GTIN accuracy is required.
Stenner 170FL5A3S is a Classic Series 170DMP5 double-head fixed-output chemical metering pump with 3/8" tubing, #5 Santoprene pump tubes, 120V power, 170 GPD fixed output, and 25 PSI maximum pressure.
170FL5A3S is a fixed-output pump. It does not have a manual feed rate dial. Output is controlled by pump run time, external controls, or system design.
170FL5A3S is a double-head Stenner Classic Series pump. The double-head configuration provides higher output than comparable single-head models.
Stenner 170FL5A3S is rated for 170 gallons per day, 7.08 gallons per hour, or approximately 15.1 ounces per minute at 60 Hz.
170FL5A3S is a low-pressure pump configuration rated for 25 PSI maximum pressure.
170FL5A3S is a 120V, 60 Hz, single-phase pump.
170FL5A3S uses #5 Santoprene pump tubes.
This pump is configured with 3/8" suction and discharge tubing.
Yes. This pump configuration includes a 20' roll of 3/8" white suction/discharge tubing.
This pump may be used for compatible chlorine feed applications when the chemical, concentration, tubing material, pressure, and installation conditions are suitable. Always verify chemical compatibility before use.
This pump may be used for compatible acid feed applications when the chemical, concentration, tubing material, pressure, and installation conditions are suitable. Always verify chemical compatibility before use.
Stenner Classic Series peristaltic pumps are designed to be self-priming when installed and used according to the manufacturer's instructions.
Stenner Classic Series pumps are designed to pump many off-gassing solutions and resist vapor lock when used within compatible application limits.
No. 170FL5A3S is the fixed-output version. 170JL5A3S is the adjustable-output version with an output range up to 170 GPD.
A fixed-output pump is useful when the desired feed rate is controlled by run time, a timer, relay, or compatible automation controller. Choose an adjustable model when manual output adjustment at the pump is needed.
Use the compatible Stenner #5 Santoprene pump tube for this pump. Verify the existing tube number before ordering replacement pump tubes.
This pump is rated for 25 PSI maximum pressure. For 25 PSI Stenner pump configurations, use the proper low-pressure injection fitting unless a different setup is specifically verified.
No. Do not exceed the 25 PSI maximum pressure rating for this pump configuration.
Yes. 170FL5A3S is a complete Stenner chemical metering pump package. Replacement pump tubes, pump heads, latches, rollers, fittings, and tubing may be sold separately for service.
Some Stenner double-head pumps use different standard and innermost pump head parts. Verify the pump head position before ordering replacement covers, rollers, pump heads, or related pump head components.
Check the required flow rate, pressure rating, voltage, tubing size, pump tube number, chemical compatibility, and whether the application requires fixed or adjustable output before ordering.
Yes. Chemical feed output should be confirmed in the field using water testing or analytical testing because actual output can vary with installation conditions.